Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 911
14 Parameter reference
14.2 Parameter list | C02960
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02960
C02962
C02963
C02964
C02965
Parameter | Name:
C02960 | Pos Track Choice
Data type: UNSIGNED_32
Index: 21615
d
= 546F
h
From software version V3.0
Changing cam data via parameterisation
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02962 | Number of Pos Data Points
Data type: UNSIGNED_32
Index: 21613
d
= 546D
h
From software version V3.0
Changing cam data via parameterisation
Display range (min. value | unit | max. value)
0 65535
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02963 | Pos Data Point Choice
Data type: UNSIGNED_32
Index: 21612
d
= 546C
h
From software version V3.0
Changing cam data via parameterisation
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02964 | Change Pos Data Point X
Data type: INTEGER_32
Index: 21611
d
= 546B
h
From software version V3.0
Changing cam data via parameterisation
Setting range (min. value | unit | max. value) Lenze setting
-214748.3647 Unit 214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02965 | Change Pos Data Point Y
Data type: INTEGER_32
Index: 21610
d
= 546A
h
From software version V3.0
Changing cam data via parameterisation
Setting range (min. value | unit | max. value) Lenze setting
-214748.3647 Unit 214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000