11 Basic drive functions
11.5 Manual job, encoderless
408
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Support for Pole position identification
( 128) in the case of torque and linear motors by means
of
movement to a machine position in which pole position identification can be carried out in a
reproducible manner and
setting of the pole position angle with the "PL touch probe signal"
11.5.1 Parameter setting
Parameterising dialog box in»Engineer«: Tab Application parameters Dialog level Overview
All basic functions Manual jog (OL)
Short overview of the parameters for manual jog, encoderless:
Parameter Info Lenze setting
Value Unit
C02770/1 EnableManualMode 0: Deactivate
C02770/2
JogPositive 0: Deactivate
C02770/3
JogNegative 0: Deactivate
C02770/4
ActivateDataBit1 0: Deactivate
C02770/5
ActivateDataBit2 0: Deactivate
C02771/1...4
Frequency
• Field frequency f
d
with which the current vector
rotates.
1.0 Hz
C02772/1...4
Start angle 0.0 °
C02773/1...4
Current
R.m.s. value of the current vector which is injected
with the parameterised frequency/starting angle.
• 100 % I
max_device
(C00022)
10.00 %
C02774/1...4
Acceleration time 1.000 s
C02775/1...4
Deceleration time 1.000 s
C02776/1...4
Max. activation time 1.000 s
C02779 Mol_SetpointCurrent - A
C02780 Mol_dnState -
C02781 ManualJogOpenLoop: Dig. signals -
Greyed out = display parameter
Stop!
At the frequency f
d
= 0 Hz, the r.m.s. value increases to 141 % of the current
parameterised in C02773/x
. As a result, the connected motor can be destroyed!
Remedy:
Activation of a derating curve in i2xt monitoring or limitation of the
parameterised current in C02773/x
to 71 % of the rated motor current. Motor
monitoring (I
2
xt) ( 215)