14 Parameter reference
14.2 Parameter list | C02523
850
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02523
C02524
C02525
C02526
C02527
Parameter | Name:
C02523 | Gearbox fac. denom.: Pos. enc.
Data type: INTEGER_32
Index: 22052
d
= 5624
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
1 2147483647 1
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02524 | Feed constant
Data type: UNSIGNED_32
Index: 22051
d
= 5623
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
0.0001 Unit/rev. 214748.3647 360.0000 Unit/rev.
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02525 | Unit
Data type: UNSIGNED_32
Index: 22050
d
= 5622
h
Drive interface
Selection list (Lenze setting printed in bold) Info
0 User-defined The text entered in C02526
is displayed for the unit.
1Incr.
2 μm
3mm
4m
5inch
6yard
7°
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02526 | User-defined unit
Data type: VISIBLE_STRING
Index: 22049
d
= 5621
h
User-defined unit which is displayed when C02525="0" is selected.
Drive interface
Read access Write access CINH PLC STOP No transfer Scaling factor: 1 Character length: 8
Parameter | Name:
C02527 | Motor mounting direction
Data type: UNSIGNED_32
Index: 22048
d
= 5620
h
Drive interface
Selection list (Lenze setting printed in bold)
0 Motor rotating CW
1Motor rotating CCW
Read access Write access CINH PLC STOP No transfer Scaling factor: 1