Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 863
14 Parameter reference
14.2 Parameter list | C02585
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02585
C02586
C02587
C02588
C02589
Parameter | Name:
C02585 | Brake control polarity
Data type: UNSIGNED_32
Index: 21990
d
= 55E6
h
Basic function "Brake control"
Selection list (Lenze setting printed in bold)
0 Not inverted
1Inverted
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02586 | Starting torque 1
Data type: INTEGER_32
Index: 21989
d
= 55E5
h
Basic function "Brake control"
Setting range (min. value | unit | max. value) Lenze setting
-21474836.47 Nm 21474836.47 0.00 Nm
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02587 | Starting torque 2
Data type: INTEGER_32
Index: 21988
d
= 55E4
h
Basic function "Brake control"
Setting range (min. value | unit | max. value) Lenze setting
-21474836.47 Nm 21474836.47 0.00 Nm
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02588 | Source of starting torque
Data type: UNSIGNED_32
Index: 21987
d
= 55E3
h
Basic function "Brake control"
Selection list (Lenze setting printed in bold)
0Starting torque 1/2
1 Stopping value
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02589 | Brake closing time
Data type: UNSIGNED_32
Index: 21986
d
= 55E2
h
Basic function "Brake control"
Setting range (min. value | unit | max. value) Lenze setting
0 ms 60000 100 ms
Read access Write access CINH PLC STOP No transfer Scaling factor: 1