Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 899
14 Parameter reference
14.2 Parameter list | C02810
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02810
Parameter | Name:
C02810 | Touch probe x: Delay time
Data type: UNSIGNED_32
Index: 21765
d
= 5505
h
The delay time set will be considered when the position is determined at the time of touch probe and will be used
to compensate for dead times, if necessary.
• Please observe the setting of the input filter for the digital inputs (C02830
).
Setting range (min. value | unit | max. value)
0 μs 7000
Subcodes Lenze setting Info
C02810/1 0 μs TP1 (DI1): Delay time
C02810/2 0 μs TP2 (DI2):Delay time
C02810/3 0 μs TP3 (DI3):Delay time
C02810/4 0 μs TP4 (DI4):Delay time
C02810/5 0 μs TP5 (DI5):Delay time
C02810/6 0 μs TP6 (DI6): Delay time
C02810/7 0 μs TP7 (DI7): Delay time
C02810/8 0 μs TP8 (DI8): Delay time
C02810/9 0 μsTPM (motor encoder): Delay time
C02810/10 0 μsTPL (pos. encoder): Delay time
Read access Write access CINH PLC STOP No transfer Scaling factor: 1