
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 611
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.7.1.1 Response
The state of the internal device control changes according to the selected response to an error,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes on:
13.7.1.2 Instance ID
The instance ID is dynamically assigned by the operating system.
Bit 31 Bit 30 Bit 29 Response
0 0 0 0: No response
0011: Fault
0102: Trouble
0 1 1 3: Quick stop by trouble
1 0 0 4: Warning locked
1015: Warning
1106: Information
1 1 1 7: System fault
Response Logbook entry Display in C00168 Pulse inhibit Controller inhibit Acknowledgeme
nt required
LED
"DRIVE ERROR"
None OFF
Information OFF
Warning
Warning locked
Quick stop by
trouble
Trouble
(after 0.5 s)
Fault
System fault Mains
switching
is required!
Bit 28 Bit 27 Bit 26 Meaning
0 0 0 Instance ID 0
0 0 1 Instance ID 1
0 1 0 Instance ID 2
0 1 1 Instance ID 3
1 0 0 Instance ID 4
1 0 1 Instance ID 5
1 1 0 Instance ID 6
1 1 1 Instance ID 7
Comentarios a estos manuales