4 Drive interface
4.2 Device commands
80
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.33 CAN module: Identify node
The C00002 = "96: CAN module: identify node" device command is used to determine the nodes
connected to the CANopen system bus interface of a CANopen communication module in module
slot MXI1 or MXI2.
The result of the CAN bus scan is displayed in C13393 (for MXI1) or in C14393 (for MXI2).
Tip!
Detailed information on the CANopen communication module (E94AYCCA) can be found in
the "CAN" Communication Manual.
Possible status displays for this device command
Related device commands
CAN module: Reset node
( 76)
CAN module: Pred.Connect.Set
( 78)
Status (C00003) Meaning
6325506 Device command in process
6291456 Device command executed successfully
6291457 General fault