6.1.1 Use of an external position encoder
The FDB_dnActPosIn_p input serves to evaluate an external encoder (CAN, SSI, Profibus) for the
position control.
• Via this input, a current actual position of an external encoder in [increments] can be directly
transferred to the encoder evaluation.
How to activate the use of the external actual position:
On the Application parameters
tab in the dialog level Overview Drive interface Machine parameters:
1. Select the "Position controller active" setting in the Position control structure list field
(C02570
), so that the position encoder is evaluated.
2. Set "From application" in the Position encoder selection list field (C00490
).
Note!
• Encoder inversion and offset selection FDB_dnPositionOffset_p also affect the
external actual position.
• If the use of the external actual position preset via FDB_dnActPosIn_p is activated, the
"Home position known" status (HM_bHomePosAvailable = TRUE) is automatically set
and homing with the basic function "Homing" cannot be activated anymore.
• If the traversing range (C02528
) is set to "Modulo", the external actual position also
has to be defined as modulo (0 … cycle-1).