11 Basic drive functions
11.13 Cam data management
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.13.4 Product/track change-over
Product change-over
The change-over to another product number is effected for all cam FBs within the application via
the basic function "Cam data management".
The change-over is effected via the input CAM_bActivateProduct on the basis of an event that is
generated from the application.
By setting the input CAM_bActivateProduct to TRUE, the product is activated with the product
number at input CAM_dnProductNumber.
[11-52] Principle: Product change-over
Track change-over
The change-over to another curve track, cam track, or position track, however, is individually
effected via the input dnTrackNumber at the respective cam function block.
For the two FBs L_CamProfiler and L_CamContactor it can be parameterised whether the track
change-over is to be effected in the next zero crossing of the x axis or immediately (Lenze
setting: in the next zero crossing).
[11-53] Principle: Track change-over
Product number
Activate product change-over
/6B&DP,QWHUIDFH
&$0BGQ3URGXFW1XPEHU
" L
&$0BE$FWLYDWH3URGXFW
Track number of the curve track
Track number of the cam track
Track number of the position track
/B&DP&RQWDFWRU
GQ7UDFN1XPEHU
"
L
/B&DP3RV0DUNHU
GQ7UDFN1XPEHU
" L
/B&DP3URILOHU
GQ7UDFN1XPEHU
" L