Lenze 9400 Manual de usuario Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 954
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
4 Drive interface
4.2 Device commands
48
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.5 Save selected application
After mains switching the controller always loads the preset start application from the memory
module, even if a different application has been active before.
With the device command C00002
= "7: Save selected application" the active application can be
defined as start application.
[4-15] "Save selected application" function
When this device command is executed, the parameter set is also saved automatically.
The number of the currently active application is displayed in C00007
.
Possible status displays for this device command
Related device commands
Activate application
( 47)
Start application
( 53)
Stop application
( 54)
* In this example, the active application 2 is defined as start application
PS
9400
RAM
Firmware Application 2*
PS
Application 3
Memory module MM
Application 1
Application 2*
PS
Status (C00003) Meaning
492802 Device command in process
458752 Device command executed successfully
458753 General fault
Vista de pagina 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 953 954

Comentarios a estos manuales

Sin comentarios