Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 835
14 Parameter reference
14.2 Parameter list | C01127
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01127
C01128
C01129
C01130
C01190
Parameter | Name:
C01127 | Service code
Data type: UNSIGNED_32
Index: 23448
d
= 5B98
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01128 | Service code
Data type: UNSIGNED_32
Index: 23447
d
= 5B97
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01129 | Service-Code
Data type: UNSIGNED_32
Index: 23446
d
= 5B96
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01130 | CAN SYNC application cycle
Data type: UNSIGNED_16
Index: 23445
d
= 5B95
h
From software version V3.0
This parameter affects the effect of the sync phase position (C01122
) regarding the instant of acceptance of the
synchronous PDOs in the application and the instant of transmission of the synchronous PDOs on the system bus
(CANopen).
The resulting PDO delay can be calculated with the following formula taking into account an internal processing
time of 150 μs: PDO delay = (C01121
- C01122 + 150 μs) modulo C01130
• For the Lenze setting, the behaviour remains as before, the sync phase position (C01122
) is always calculated
modulo 1000.
• The set value is automatically rounded down to multiples of 1000 μs.
Effect of C01130 on the sync phase position
Note: Setting the application cycle to a higher value than the sync cycle time (C01121) results in undefined
behaviour. The same applies if the value set for the sync phase position (C01122
) is higher than the sync cycle time
(C01121
). In this case, the drive usually cannot send synchronous PDOs on the system bus anymore.
"CAN on board" system bus: sync telegram
Setting range (min. value | unit | max. value) Lenze setting
1000 μs 65000 1000 μs
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01190 | Motor thermal sensor
Data type: UNSIGNED_32
Index: 23385
d
= 5B59
h
Motor temperature monitoring
Selection list (Lenze setting printed in bold) Info
0 KTY83-110 Lenze standard KTY83-110 (MDSKX, MCS06)
1 Spec. characteristic Characteristic defined via C01191
and C01192.
2 KTY83-110 + 2 x PTC Lenze standard KTY83-110 + 2 x PTC 150°C (MCS09-
MCS19)
Read access Write access CINH PLC STOP No transfer Scaling factor: 1