11 Basic drive functions
11.13 Cam data management
562
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.13.3.2 Online change mode
During running operation, new cam data can be downloaded from »Engineer« to the controller if
the controller is in storage mode 1 or 2.
If the cam data are provided with an access protection, the user password has to be entered first.
Access protection
( 555)
The time when the new/altered cam data are accepted depends on the online change mode set
in C02905
.
Mode 16: Automatic activation with CINH
In the Lenze setting, the online change mode "Automatic activation with CINH" is set in C02905
, i.e.
the new cam data are accepted automatically as soon as the controller is inhibited.
[11-49] Online change mode "Automatic activation with CINH"
Note!
If the controller is in storage mode 3, the "Online change" function is deactivated:
The online change mode set in C02905
is ineffective.
•In C02906
the status "999: Online change deactivated" is displayed.
For the download of new cam data, controller inhibit is required.
The cam data are accepted immediately after download.
Memory distribution
( 554)
Download/change of cam data active
Internal recalculation of cam data active
Automatic activation with controller inhibit
W
&$0BE$FWLYDWH1HZ'DWD
W
&$0BE%XV\
W
&$0BE1HZ'DWD$YDLODEOH
W
2QOLQHFKDQJH
W
&DPGDWD%&DPGDWD$
no
W
&,1+
p