Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 905
14 Parameter reference
14.2 Parameter list | C02902
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02902
C02903
C02905
Parameter | Name:
C02902 | Timestamp
Data type: UNSIGNED_32
Index: 21673
d
= 54A9
h
From software version V3.0
Basic function "Cam data management
"
Display range (min. value | unit | max. value)
0 4294967295
Subcodes Info
C02902/1 Time stamp of the cam data in the controller
C02902/2 Time stamp of the cam data which are currently being
processed in the controller.
C02902/3 Time stamp of the cam data in the controller which have
already been converted into the internal format.
C02902/4 Time stamp of the cam data in the memory module
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02903 | GUID
Data type: OCTET_STRING
Index: 21672
d
= 54A8
h
From software version V3.0
Basic function "Cam data management
"
Display range (min. value | unit | max. value)
Subcodes Info
C02903/1 GUID of the cam data in the controller
C02903/2 GUID of the cam data which are currently being
processed in the controller.
C02903/3 GUID of the cam data in the controller which have
already been converted into the internal format.
C02903/4 GUID of the cam data in the memory module
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02905 | Online Change Mode
Data type: UNSIGNED_32
Index: 21670
d
= 54A6
h
From software version V3.0
Basic function "Cam data management": Online change mode
Selection list (Lenze setting printed in bold)
10 Manual activation
15 Automatic activation
16 Automatic activation with controller
inhibit
Read access Write access CINH PLC STOP No transfer Scaling factor: 1