Internal variables of the motor control (oscilloscope signals)
The red numbers in brackets listed in the signal flow stand for internal variables of the motor
control, which you can record by means of the Oscilloscope
for purposes of diagnostics and
documentation.
( 579)
No. Variable of the motor control Meaning
(1) Torque.dnTotalTorqueAdd Additive torque feedforward control value
(2) Torque.dnTorqueSetpoint Torque setpoint
(3) Position.dnActualLoadPos Actual position
(4) Position.dnPositionSetpoint Position setpoint
(5) Position.dnActualMotorPos Current motor position
(6) Position.dnContouringError Following error
(7) Speed.dnOutputPosCtrl Output signal - phase controller
(8) Speed.dnSpeedSetpoint Speed setpoint
(9) Speed.dnActualMotorSpeed Current motor speed