11 Basic drive functions
11.12 Brake control
546
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[11-44] Process example: speed follower is active quick stop activation speed follower is active
Actual speed value
Actual speed value if the quick stop braking current is parameterised too low (C00975
)
C00105
: Quick stop decel. time
C02589
: Brake closing time
C00975
: Quick stop braking current
C00974
: Braking current
t
t
Enable speed follower
t
Speed setpoint
Speed follower active
Quick stop active
DC brake active
t
t
CINH
t
DC brake current
01
Note!
The quick stop braking current in C00975 has to be set so that the drive can be
decelerated from the maximum operating speed to standstill within the deceleration
time for quick stop set in C00105
!
Comentarios a estos manuales