13 Diagnostics & fault analysis
13.7 Error messages of the operating system
620
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x007b0023 8060963 Load encoder: Module selected in C00490 is not available Fault -
0x00900004
9437188 Loading of Lenze setting failed Fault -
0x00650000
6619136 Logbook: Overflow Information -
0x00650001
6619137 Logbook: Reset (read error) Information -
0x00650002
6619138 Logbook: Reset (version error) Information -
0x00910001
9502721 Mains voltage is switched off Information -
0x00910000
9502720 Mains voltage is switched on Information -
0x00b80011
12058641 Maximum acceleration exceeded Information C02716/3
0x00b80010 12058640 Maximum speed exceeded Information C02716/3
0x00680017 6815767 Memory module has been changed Information or warning locked if
the hardware type has also
changed.
-
0x00680006
6815750 Memory module has been removed System fault -
0x00680002
6815746 Memory module is defective or missing Fault -
0x0068000c
6815756 Memory module is defective or missing System fault -
0x00650003
6619139 Memory module is missing Information -
0x0068001c
6815772 Memory module: Faulty file system Fault -
0x007c0000
8126464 Memory module: file system has been formatted Information -
0x007c0001
8126465 Memory module: File system has been restored Information -
0x00b80003
12058627 Motor brake: Angular drift with closed brake too high Quick stop by trouble -
0x00b80004
12058628 Motor brake: Autom. activated after waiting time has elapsed Information -
0x00b80005
12058629 Motor brake: Status monitoring error Quick stop by trouble -
0x007b0013
8060947 Motor control: Task overflow System fault -
0x007b0003
8060931 Motor data are inconsistent Information -
0x007b0017
8060951 Motor data are inconsistent Information -
0x007b004c
8061004 Motor disconnected No response C00597
0x007b0024 8060964 Motor encoder: Module selected in C00495 is not available Fault -
0x00780003
7864323 Motor load I²xt > C00120 Fault -
0x00780002
7864322 Motor load I²xt > C00127 Warning C00606
0x007b0038 8060984 Motor parameter identification cancelled Fault -
0x007b0025
8060965 Motor temperature: Module selected in C01193 is not available Fault -
0x007b001e
8060958 Motor: Actual current value > C00620 Fault C00619
0x007b0020 8060960 Motor: Actual speed value > C00596 Fault C00607
0x007b000b 8060939 Motor: Calculated e.m.f. factor unrealistic Information -
0x007b000d
8060941 Motor: Calculated flux factor unrealistic Information -
0x007b0019
8060953 Motor: Calculated leakage inductance unrealistic Information -
0x007b0001
8060929 Motor: Calculated motor impedance unrealistic Information -
0x007b0002
8060930 Motor: Calculated mutual inductance unrealistic Information -
0x007b000a
8060938 Motor: Calculated mutual inductance unrealistic Information -
0x007b0009
8060937 Motor: Calculated rotor resistance unrealistic Information -
0x007b000c
8060940 Motor: Calculated rotor time constant unrealistic Information -
0x007b0006
8060934 Motor: Device current too low for rated magnetisation Information -
0x00770003
7798787 Motor: Overtemperature Fault C00583
0x007b0004 8060932 Motor: Phase resistance too high Information -
0x0077000f
7798799 Motor: PTC has triggered No response C00585
0x007b0007 8060935 Motor: Rated current < rated magnetisation current Information -
0x00770002
7798786 Motor: Temperature > C00121 Warning C00584
0x0077000c 7798796 Motor: thermal detector is defective Fault C00594
0x008c0017 9175063 MXI1: CAN module is missing or incompatible Fault C00615/2
0x008c0013 9175059 MXI1: Digital frequency module is missing or incompatible Fault C00615/2
0x008c0011 9175057 MXI1: Ethernet module is missing or incompatible Fault C00615/2
0x008c0015 9175061 MXI1: ICM module is missing or incompatible Fault C00615/2
0x00680004 6815748 MXI1: Module changed during operation Warning locked -
hex dec Error message Response (Lenze setting) can be set in