Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 573
11 Basic drive functions
11.14 Pole position identification
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.14.2 Parameter setting
Parameterisation dialog in »Engineer«: Tab Application parameters Dialog level Overview
All basic functions Pole position identification
Short overview of parameters for pole position identification:
11.14.3 Execute pole position identification
Requirements
The controller inhibit is active.
The controller has the "Controller not ready" function state.
The basic function "Pole position identification" is part of the active application.
No other basic function is active.
Activate basic function
To request the control via the basic function, the PPI_bEnable enable input in the application must
be set to TRUE.
If no other basic function is active, a change-over to the "Identification of pole position active"
function state is effected and an identification of pole position can be carried out via the control
inputs.
A successful change to the function state "Pole position identification" is displayed by a TRUE
signal at the PPI_bEnabled status output.
Parameter Info
C02785
Activation of PPI
C02786
Mode of PPI
C02787 Ppi_dnState
C02788 PolePosition Setpoint
C02789 PolePositionIdentification: Dig. signals
Greyed out = display parameter