Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 709
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Int. overflow C02713 (max. dist. manual control) [0x00b8002c]
Int. overflow C02642 (home position) [0x00b8002d]
Int. overflow C02643 (homing: Target position) [0x00b8002e]
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 44
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02713
.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 45
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02642
.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 46
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02643
.