4 Drive interface
4.2 Device commands
76
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.29 CAN module: Reset node
The C00002 = "92: CAN module: reset node" device command is used to reinitialise the CANopen
interface of a CANopen communication module in module slot MXI1 or MXI2, which is required, for
instance, after the data transfer rate, node address, or identifiers have been changed.
Tip!
Detailed information on the CANopen communication module (E94AYCCA) can be found in
the "CAN" Communication Manual.
Possible status displays for this device command
Related device commands
CAN module: Pred.Connect.Set
( 78)
CAN module: Identify node
( 80)
Status (C00003) Meaning
6063362 Device command in process
6029312 Device command executed successfully
6029313 General fault
6068736 CAN fault
...
6068991 CAN fault