9 "CAN on board" system bus
9.10 Implemented CANopen objects | I-1A02
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I-1A02
The object I-1A02 serves to send parameter data as TPDO3.
For data telegram assignment, see object I-1A00
.
I-1A03
The object I-1A03 serves to transmit parameter data as TPDO4.
For data telegram assignment, see object I-1A00
.
Index:
I-1A02
Name:
TPDO3 mapping parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: number of mapped application
objects in PDO
00 8rwU8
1 ... 8: application object 1 ... 8 0 0 4294967295 rw U32
Subindex Meaning
0 Number of mapped objects
1 ... 8 Mapping entries 1 ... 8 for RPDO4
Index:
I-1A03
Name:
TPDO4 mapping parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: number of mapped application
objects in PDO
00 8rwU8
1 ... 8: application object 1 ... 8 0 0 4294967295 rw U32
Subindex Meaning
0 Number of mapped objects
1 ... 8 Mapping entries 1 ... 8 for TPDO4