Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 737
14 Parameter reference
14.2 Parameter list | C00058
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00058
C00059
C00060
C00061
C00062
C00063
Parameter | Name:
C00058 | Pole position
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Setting range (min. value | unit | max. value)
-179.9 ° 179.9
Subcodes Lenze setting Info
C00058/1 -90.0 ° Resolver pole position
C00058/2 0.0 ° Encoder pole position
C00058/3 0.0 ° Module pole position
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00059 | Motor - number of pole pairs
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display range (min. value | unit | max. value)
0 200
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00060 | Rotor position
Data type: INTEGER_32
Index: 24515
d
= 5FC3
h
Display range (min. value | unit | max. value)
0 2047
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_32
Index: 24514
d
= 5FC2
h
Display range (min. value | unit | max. value)
-200 °C 200
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00062 | Temperature inside the controller
Data type: INTEGER_32
Index: 24513
d
= 5FC1
h
Display range (min. value | unit | max. value)
-200 °C 200
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00063 | Motor temperature
Data type: INTEGER_32
Index: 24512
d
= 5FC0
h
Motor temperature monitoring
Display range (min. value | unit | max. value)
-200 °C 200
Read access Write access CINH PLC STOP No transfer Scaling factor: 1