13 Diagnostics & fault analysis
13.7 Error messages of the operating system
676
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Lenze setting loaded [0x00900001]
Parameter set saved [0x00900002]
Parameter set loaded [0x00900003]
Loading of Lenze setting failed [0x00900004]
Parameter set restored [0x00900005]
Module ID (decimal) Error ID (decimal)
144: Parameter manager 1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Lenze setting has been loaded. - (Information only)
Module ID (decimal) Error ID (decimal)
144: Parameter manager 2
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter set has been saved. - (Information only)
Module ID (decimal) Error ID (decimal)
144: Parameter manager 3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter set has been loaded. - (Information only)
Module ID (decimal) Error ID (decimal)
144: Parameter manager 4
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Lenze setting of a parameter is not within the valid
limits.
Eliminate error in the application and retransfer
application to controller.
Module ID (decimal) Error ID (decimal)
144: Parameter manager 5
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
An error has occurred while loading the selected
parameter set.
Transfer parameter set from Engineer to the controller
and save with C00002
="11".