Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 765
14 Parameter reference
14.2 Parameter list | C00312
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00312
C00313
Parameter | Name:
C00312 | CAN TPDO2 mask byte x
Data type: BITFIELD_8
Index: 24263
d
= 5EC7
h
A mask can be parameterised for each byte of the TPDO2 in the assigned subcode.
• In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.
• Mask "0x0" means that no bit of the corresponding byte actuates the transmission.
• Mask "0xff" means that every bit of the corresponding byte can actuate the transmission.
"CAN on board" system bus
Setting range
0x00 0xFF
Value is bit-coded:
Bit 0 Mask bit 0
... ...
Bit 7 Mask bit 7
Subcodes Lenze setting Info
C00312/1 0x00 Mask for byte 1 ... byte 8 of TPDO2
C00312/...
C00312/8
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00313 | CAN TPDO3 mask byte x
Data type: BITFIELD_8
Index: 24262
d
= 5EC6
h
A mask can be parameterised for each byte of the TPDO3 in the assigned subcode.
• In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.
• Mask "0x0" means that no bit of the corresponding byte actuates the transmission.
• Mask "0xff" means that every bit of the corresponding byte can actuate the transmission.
"CAN on board" system bus
Setting range
0x00 0xFF
Value is bit-coded:
Bit 0 Mask bit 0
... ...
Bit 7 Mask bit 7
Subcodes Lenze setting Info
C00313/1 0x00 Mask for byte 1 ... byte 8 of TPDO3
C00313/...
C00313/8
Read access Write access CINH PLC STOP No transfer Scaling factor: 1