Lenze 9400 Manual de usuario Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 954
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 71
4 Drive interface
4.2 Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.25 Determine motor parameters
The C00002 = "72: Determine motor parameters" device command is used to automatically
determine the motor parameters for a third-party motor that are listed in the following table – if
they are not known:
Tip!
Detailed information about the automatic determination of the motor parameters can be
found in the chapter "Motor interface" in the subchapter "Determining the motor
parameters". ( 138)
Possible status displays for this device command
Parameter Info ASM SM
C00079
Mutual motor inductance
C00082
Motor rotor resistance
C00084
Motor stator resistance 
C00085
Motor stator leakage inductance 
C00091
Motor cosine phi
C00092
Motor magnetising current
Status (C00003) Meaning
4752642 Device command in process
4718592 Device command executed successfully
4718593 General fault
4758290 Motor identification cannot be started since the current controller test mode is active.
4758291 Motor identification cannot be started since the V/f test mode is active.
4758292 Motor identification cannot be started because pole position identification is active.
4758293 Motor identification has been aborted.
4758294 Motor identification has been aborted by fault.
4758332 Motor identification aborted due to inconsistent motor parameters.
This error message is only available from software version V7.0 onwards.