14 Parameter reference
14.2 Parameter list | C00812
820
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00812
C00813
C00814
C00815
C00816
Parameter | Name:
C00812 | MCTRL_dnMotorPosRefValue
Data type: UNSIGNED_32
Index: 23763
d
= 5CD3
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
0 Incr. 4294967295
Subcodes Info
C00812/1 LOW word
C00812/2 High word
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00813 | MCTRL_dnLoadPosRefValue
Data type: UNSIGNED_32
Index: 23762
d
= 5CD2
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
0 Incr. 4294967295
Subcodes Info
C00813/1 LOW word
C00813/2 High word
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00814 | MCTRL_dnBoost
Data type: INTEGER_32
Index: 23761
d
= 5CD1
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-1000 V 1000
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00815 | MCTRL_dnSpeedCtrlIntegrator
Data type: INTEGER_32
Index: 23760
d
= 5CD0
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-2147483.647 Nm 2147483.647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C00816 | MCTRL_dnFieldWeak
Data type: INTEGER_32
Index: 23759
d
= 5CCF
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100