14 Parameter reference
14.2 Parameter list | C02621
870
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02621
C02622
C02623
C02624
C02625
Parameter | Name:
C02621 | Manual jog: Speed 2
Data type: INTEGER_32
Index: 21954
d
= 55C2
h
Basic function "Manual jog"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s 214748.3647 720.0000 Unit/s
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02622 | Manual jog: Acceleration
Data type: INTEGER_32
Index: 21953
d
= 55C1
h
Basic function "Manual jog"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 360.0000 Unit/s²
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02623 | Manual jog: Deceleration
Data type: INTEGER_32
Index: 21952
d
= 55C0
h
Basic function "Manual jog"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 1440.0000 Unit/s²
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02624 | Manual jog: S-ramp time
Data type: UNSIGNED_32
Index: 21951
d
= 55BF
h
Basic function "Manual jog"
Setting range (min. value | unit | max. value) Lenze setting
0.000 s 10.000 0.100 s
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02625 | Manual jog: Step size
Data type: INTEGER_32
Index: 21950
d
= 55BE
h
From software version V5.0
Step distance for "Manual jog with step limitation
" mode.
Basic function "Manual jog
"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit 214748.3647 360.0000 Unit
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000