Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 327
9 "CAN on board" system bus
9.8 Diagnostics
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.8 Diagnostics
The display parameters listed in the following table serve to request current information on the
system bus for diagnostic purposes, e.g. using the keypad, via a bus system, or using »Engineer«
(when an online connection has been established to the controller).
• The »Engineer« parameter list and the keypad contain these parameters in the category
CAN CAN management.
• A detailed description of these parameters can be found in the chapter "Parameter reference
".
( 713)
Parameter Display
C00345 CAN error
C00359 CAN status
C00360/1 CAN stuffing bit error counter
C00360/2 CAN format error counter
C00360/3 CAN acknow. error counter
C00360/4 CAN bit 1 error counter
C00360/5 CAN bit 0 error counter
C00360/6 CAN CRC error counter
C00360/7 CAN Tx telegram counter
C00360/8 CAN Rx telegram counter
C00361/1 CAN bus load: Current node load in Tx direction
C00361/2 CAN bus load: Current node load in Rx direction
C00361/3 CAN bus load: Current node load of faulty telegrams
C00361/4 CAN bus load: Node peak load in Tx direction
C00361/5 CAN bus load: Node peak load in Rx direction
C00361/6 CAN bus load: Node peak load of faulty telegrams
C00390 CAN error register (DS301V402)
Comentarios a estos manuales