13 Diagnostics & fault analysis
13.5 Monitoring
608
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.5.1 Setting the error response
If a monitoring function responds, the response set for this monitoring function (quick stop by
trouble, warning, fault, etc.) is triggered.
• For many monitoring functions the response can be individually parameterised via parameters.
Tip!
The table in chapter "Short overview (A-Z)
" contains the error messages for which the
response can be set .
( 615)
Warning thresholds
Some of the monitoring functions are activated if a defined warning threshold (e.g. temperature)
has been exceeded.
• The corresponding preset threshold values can be changed via the following parameters:
Parameter Info
C00120
Motor overload protection (I²xt)
C00121
Motor temp. warning threshold
C00122
Heatsink temp. warn. threshold
C00123
Device utilisation warning threshold
C00126
CPU temp. warning threshold
C00127 Mot. overload warning threshold
C00128
Thermal time constant of motor
C00174
Undervoltage (LU) threshold
C00570 Warning thres. brake transistor
C00572
Warning thres. brake resistor
C00576
Speed monitoring tolerance
C00596
Threshold max. speed reached
C00599
Motor phase failure threshold
C00620
Max. motor current threshold
Comentarios a estos manuales