Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 805
14 Parameter reference
14.2 Parameter list | C00614
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00614
C00615
C00618
Parameter | Name:
C00614 | Resp. to CAN life guarding error
Data type: UNSIGNED_8
Index: 23961
d
= 5D99
h
Response of slave if node guarding request is not received.
"CAN on board" system bus: node guarding protocol
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00615 | Resp. to imp. device config.
Data type: UNSIGNED_32
Index: 23960
d
= 5D98
h
Selection list
1Fault
3 Quick stop by trouble
4 Warning locked
6 Information
0 No response
Subcodes Lenze setting Info
C00615/1 0: No response Reserved
C00615/2 1: Fault Resp. to imp. module in MXI1
C00615/3 1: Fault Resp. to imp. module in MXI2
C00615/4 0: No response Reserved
C00615/5 0: No response Reserved
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00618 | No. of CRC cycles
Data type: UNSIGNED_32
Index: 23957
d
= 5D95
h
Display range (min. value | unit | max. value)
0 4294967295
Read access Write access CINH PLC STOP No transfer Scaling factor: 1