6 Encoder evaluation
6.3 Parameter setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of the parameters:
Parameter Info Lenze setting
Value Unit
C00422 Encoder type SSI encoder
C00423
SSI encoder: Bit rate 400 kbps
C00424
SSI encoder: Data word length 24 Bit
C00435/1
SSI enc.: Partword 1 start 0
C00436/1
SSI enc.: Partword 1 length 24
C00437/1
SSI enc.: Partword 1 coding gray coded
C00490
Position encoder selection Encoder on X8
C00495
Motor encoder selection Resolver on X7
C02522
Gearbox factor numerator: position encoder 1200
C02523
Gearbox factor denominator: position encoder 400
C02524
Feed constant 1200 mm
C02570
Position control structure Position controller is active
C05271 Encoder evaluation 32-bit encoder signal
C05272 Encoder mounting position Left
C05273 Single turn resolution 4096 Steps/rev
C05274 Resolution Multiturn 4096 Rev