Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 875
14 Parameter reference
14.2 Parameter list | C02645
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02645
C02646
C02647
C02648
C02649
Parameter | Name:
C02645 | Homing: Acceleration 1
Data type: INTEGER_32
Index: 21930
d
= 55AA
h
Basic function "Homing"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 720.0000 Unit/s²
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02646 | Homing: Speed 2
Data type: INTEGER_32
Index: 21929
d
= 55A9
h
Basic function "Homing"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s 214748.3647 0.0000 Unit/s
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02647 | Homing: Acceleration 2
Data type: INTEGER_32
Index: 21928
d
= 55A8
h
Basic function "Homing"
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 360.0000 Unit/s²
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02648 | Homing: S-ramp time
Data type: INTEGER_32
Index: 21927
d
= 55A7
h
Basic function "Homing"
Setting range (min. value | unit | max. value) Lenze setting
0 ms 10000 100 ms
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02649 | Homing: Torque limit
Data type: INTEGER_32
Index: 21926
d
= 55A6
h
Basic function "Homing"
Setting range (min. value | unit | max. value) Lenze setting
0.00 % 200.00 10.00 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 100