11 Basic drive functions
11.5 Manual job, encoderless
410
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.2.1 Requirements
• Check and, if necessary, adjust the basic parameterisation:
• Optimisation of the current controller in the case of non-Lenze motors or motors that are not
included in the »Engineer« motor catalogue. Optimising the current controller
( 178)
• Parameterisation of motor monitoring corresponding to the existing motor with the
monitoring response "Fault". Motor monitoring (I
2
xt) ( 215)
• This function is especially important for monitoring the permissible r.m.s. current load on
motors at f
d
=0Hz.
• Activation of maximum current monitoring with the monitoring response "Fault" in the case
of non-Lenze motors or motor that are not included in the »Engineer« motor catalogue.
Maximum current monitoring
( 230)
• Activation of motor temperature monitoring via PTC and/or KTY. Motor temperature
monitoring ( 222)
• The controller inhibit is active.
• The controller is in the "Controller not ready" stateDevice states
( 97).
• The basic function "Manual jog (OL)" is part of the active application; see Internal interfaces
| "LS_ManualJogOpenLoop" system block ( 414).
• No other basic function is active.
11.5.2.2 Activation
In order to request the control via the basic function, the MOL_bEnable enable input in the
application must be set to TRUE or C02770/1
to "1".
• If no other basic function is active, a changeover to the function state "Manual jog, encoderless
active" takes place and controlled traversing can be carried out by means of the control inputs
or by writing values into C02770/2...5
.
• A successful changeover to the function state"Manual jog, encoderless active" is indicated by a
TRUE signal at the status output MOL_bEnabled.