11 Basic drive functions
11.12 Brake control
522
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.12.2.1 Operating mode
Various operating modes are available in C02580 for different applications and tasks:
• Mode 0: Brake control is switched off
( 537)
• Mode 1/11: Direct control of the brake
( 538)
• Without a specific logic or automatic system, can for instance be used to carry out a simple
check on whether the brake switches correctly.
• Mode 2/12: Automatic control of the brake
( 539)
• The normal mode for the control of mech. holding brakes with and without holding torque
precontrol.
Function extension from software version V3.0:
• Mode 22: Automatic DC-injection braking
( 544)
• DC-injection braking for V/f control and sensorless vector control.
C02602 Source for feedf. control brake
C02603
Threshold 1 for opening brake
C02604
Threshold 2 for opening brake
C02605/1
Acceleration time - brake test
C02605/2
Duration of constant torque - brake test
C02605/3
Deceleration time - brake test
Parameter Info