13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
DFIN (MXI1): Track error A-/A [0x00990000]
DFIN (MXI1): Track error B-/B [0x00990001]
DFIN (MXI1): Track error Z-/Z [0x00990002]
DFIN (MXI1): Signal error enable/lamp control [0x00990003]
Module ID (decimal) Error ID (decimal)
153: Extension module - digital frequency in MXI1 0
Response (Lenze setting printed in bold) Setting: C13040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for track A.
• Check signal cable for track A.
•Check encoder.
Module ID (decimal) Error ID (decimal)
153: Extension module - digital frequency in MXI1 1
Response (Lenze setting printed in bold) Setting: C13040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for track B.
• Check signal cable for track B.
•Check encoder.
Module ID (decimal) Error ID (decimal)
153: Extension module - digital frequency in MXI1 2
Response (Lenze setting printed in bold) Setting: C13040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for track Z.
• Check signal cable for track Z.
•Check encoder.
Module ID (decimal) Error ID (decimal)
153: Extension module - digital frequency in MXI1 3
Response (Lenze setting printed in bold) Setting: C13041 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for the
"Enable" signal or no "Enable" signal available.
• Check signal cable for "Enable" signal.
•Check encoder.