Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 727
14 Parameter reference
14.2 Parameter list | C00003
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3900674 Device command in process 59: Resolver error identification
3866624 Device command executed successfully
3866625 General fault
3906358 Resolver error identification cannot be executed since
the wrong control type is active (no servo control).
3906359 Resolver error identification cannot be executed since an
error or trouble is active.
3906360 Resolver error identification cannot be executed because
another identification is already active.
3906361 Resolver error identification cannot be executed because
of too small speed (< 500 rpm).
4587520 Device command executed successfully 70: Load Lenze INV characteristic
4587521 General fault
4621570 Device command in process
4653056 Device command executed successfully 71: Calculate inv. characteristic
4653057 General fault
4687106 Device command in process
4692754 The calculation of the inverter characteristic cannot be
started since the current controller test mode is active.
4692755 The calculation of the inverter characteristic cannot be
started since the V/f test mode is active.
4692756 The calculation of the inverter characteristic cannot be
started since the pole position identification is active.
4692757 Calculation of the inverter characteristic has been
aborted.
4692758 Calculation of the inverter characteristic has been
interrupted by error.
4692789
From software version
V5.0
Detected inverter error characteristic exceeds internal
limits. This situation can for instance occur if the motor
power is very much lower than the device power.
4718592 Device command executed successfully 72: Determine motor parameters
4718593 General fault
4752642 Device command in process
4758290 Motor identification cannot be started since the current
controller test mode is active.
4758291 Motor identification cannot be started since the V/f test
mode is active.
4758292 Motor identification cannot be started because pole
position identification is active.
4758293 Motor identification has been aborted.
4758294 Motor identification has been aborted by fault.
4758332
From software version
V7.0
Motor identification aborted due to inconsistent motor
parameters.
5046272 Device command executed successfully 77: Calculate current controller
parameters
5046273 General fault
5080322 Device command in process
5086002 At least one calculated value is outside the valid setting
range.
5086003 Stator resistance (C00084
) too small (zero).
Status Meaning Device command