Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 697
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CAN module (MXI2) SDO server: Faulty configuration [0x00b10000]
CAN module (MXI2) SDO client: Faulty configuration [0x00b20000]
PLC configuration invalid [0x00b80000]
Positive limit switch has triggered [0x00b80001]
Module ID (decimal) Error ID (decimal)
177: CAN module in MXI2: CAN-SDO server 0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CANopen communication module in MXI2: In the CAN
SDO server a configuration error has occurred.
• Faulty project download.
• Invalid SDO server settings according to DS301V402
in the Engineer or PLC Designer.
• Repeat download.
• Correct CAN settings in the project and regenerate
project.
Module ID (decimal) Error ID (decimal)
178: CAN module in MXI2: CAN-SDO client 0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CANopen communication module in MXI2: In the CAN
SDO client a configuration error has occurred.
• Faulty project download.
Invalid SDO client settings according to DS301V402 in
the Engineer or PLC Designer.
• Repeat download
• Correct CAN settings in the project and regenerate
project.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
An invalid control configuration has occurred. Load a different application.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The travel range limit switch in positive traversing
direction has tripped.
Reset fault message and retract limit switch.