14 Parameter reference
14.2 Parameter list | C02528
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02528
C02529
C02530
Parameter | Name:
C02528 | Traversing range
Data type: UNSIGNED_32
Index: 22047
d
= 561F
h
Drive interface
Selection list (Lenze setting printed in bold)
0 Unlimited
1 Limited
2Modulo
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02529 | Position encoder mounting dir.
Data type: UNSIGNED_32
Index: 22046
d
= 561E
h
Drive interface
Selection list (Lenze setting printed in bold)
0 Encoder rotating CW
1 Encoder rotating CCW
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02530 | Active function state
Data type: INTEGER_32
Index: 22045
d
= 561D
h
Displays the basic drive function that currently controls the drive.
Basic drive functions
: Internal state machine
Selection list (read only)
0 Program stopped
1 Initial/boot state active
2 Torque follower active
3 Speed follower active
4 Position follower active
5 Setpoint follower active
6 Positioning active
7 Homing active
8 Manual jog active
9 Brake test active
10 Drive at standstill
11 Drive is stopped
12 Quick stop active
13 Reserve 1
14 Controller is not ready
15 Initialisation
16 Fault
17 Manual control open loop active
18 Pole position identification active
Read access Write access CINH PLC STOP No transfer Scaling factor: 1