11 Basic drive functions
11.4 Manual jog
402
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.4.3.1 Manual jog in positive/negative direction
In the "Manual jog active" function state the drive can be traversed manually according to the
following truth table via the control inputs:
MAN_bJogNegative MAN_bJogPositive MAN_bActivateJogSpeed2
Function
FALSE FALSE - Stop
• The drive is braked to standstill with the
deceleration set.
FALSE TRUE FALSE Manual jog
•In positive direction
• Using speed 1 (C02620
)
TRUE Manual jog
•In positive direction
• Using speed 2 (C02621
)
TRUE FALSE FALSE Manual jog
•In negative direction
• Using speed 1 (C02620
)
TRUE Manual jog
•In negative direction
• Using speed 2 (C02621
)
TRUE TRUE - When both inputs are set to TRUE at the
same time:
• The drive is braked to standstill with the
deceleration set.
If not both inputs are set to TRUE at the same
time:
• The drive continues to traverse in the
direction that was selected first.
Note!
In the standard technology applications "Actuating drive – speed" and "Actuating drive
– torque", in the Lenze setting the control inputs are linked to the following digital
inputs:
• DI6: Activate manual mode
• DI7: Manual jog in positive direction
• DI8: Manual jog in negative direction
Comentarios a estos manuales