Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 159
5 Motor interface
5.4 Servo control (SC)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.4.2 Signal flow (servo control for synchronous motor)
[5-6] Signal flow - servo control for synchronous motor
See also: Signal flow - encoder evaluation ( 240)
Signal flow - speed follower
( 494)
Signal flow - torque follower
( 499)
Signal flow - position follower
( 487)
MCTRL_dnInputJerkCtrlC00776
C00274
C00270/1
C00271/1
C00272/1
C00270/2
C00271/2
C00272/2
(1) (2) (3)
C02559/1...2
C00695
C00052
M
I
a+b
22
usq
usd
C00075
C00093
C00783
C00018
C00074
C00079
C00091
(4)
(5)
(10)
(11)(7)
(6)
(14)
M
G
Vp
Tn
Vp
Tn
C00076
C00075
C00076
MI_dnTorqueHighLimit_n
MI_dnTorqueLowLimit_n
MI_dnTorqueSetpoint_n
MI_dnFilteredTorqueSetpoint_n
MI_bCurrentSetpointLimited
a+b
22
MI_dnActualMotorCurrent_n
MI_dnActualMotorVoltage_n
MCTRL_dwMotorVoltageAct
MCTRL_dnImotActC00780
C00054
MI_bTorqueSetpointLimited
0
1
C00092
0A
(8)
(9)
Max. acceleration change
Bandwitdh 1 Bandwidth 2
Torque setpoint
Current controller
Current controller
Voltage limit
Rotating field frequency
Actual Q-current
Actual D-current
Motor type
Motor voltage
Pilot control current controller
Switching frequency
Internal torque limit
Fieldweaking
Coordinate
transformation
Motor current
Magnetising current
Field
current
calculation
Comentarios a estos manuales