Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 595
12 Oscilloscope
12.6 Variables of the motor control (oscilloscope signals)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.6 Variables of the motor control (oscilloscope signals)
The system variables of the internal motor control listed in the following table can be recorded with
the oscilloscope for diagnostic and documentation purposes.
Tip!
The exact position of a variable in the motor control can be obtained from the
corresponding signal flow.
Note!
In comparison to all other variable values, the system variables of the internal motor
control have a cycle offset of 2 ... 3 ms!
Variable of the motor control Meaning
Signal flow - servo control for synchronous motor ( 159)
Signal flow - servo control for asynchronous motor
( 161)
Common.dnActualFlux Actual flux value
Common.dnFluxSet Flux setpoint
Current.dnActualCurrentPhaseU Actual motor current (phase U)
Current.dnActualCurrentPhaseV Actual motor current (phase V)
Current.dnActualCurrentPhaseW Actual motor current (phase W)
Current.dnActualDirectCurrent Actual D current
Current.dnActualQuadratureCurrent Actual Q current
Current.dnDirectCurrentSet D current setpoint
Current.dnQuadratureCurrentSet Q current setpoint
Torque.dnActualMotorTorque Actual torque
Torque.dnFilteredTorqueSetpoint Filtered torque setpoint
Torque.dnInputNotchFilter1 Torque setpoint at the band-stop filter input 1
Torque.dnInputNotchFilter2 Torque setpoint at the band-stop filter 2 input
Voltage.dnActualDCBusVoltage Actual DC-bus voltage
Voltage.dnActualMotorVoltage Current motor voltage
Voltage.dnOutputQuadratureCurrentCtrl Q-output voltage of the current controller
Voltage.dnOutputDirectCurrentCtrl D-output voltage of the current controller
Voltage.dnDirectVoltage D voltage
Voltage.dnQuadratureVoltage Q voltage