14.2 Parameter list | C02775
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02775
C02776
C02779
C02780
Parameter | Name:
C02775 | Deceleration time
Data type: INTEGER_32
Index: 21800
d
= 5528
h
From software version V7.0
Basic function "Manual jog open loop
"
Setting range (min. value | unit | max. value)
0.001 s 2147483.647
Subcodes Lenze setting Info
C02775/1 1.000 s Deceleration time 1
C02775/2 1.000 s Deceleration time 2
C02775/3 1.000 s Deceleration time 3
C02775/4 1.000 s Deceleration time 4
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02776 | Time
Data type: INTEGER_32
Index: 21799
d
= 5527
h
From software version V7.0
Basic function "Manual jog open loop
"
Setting range (min. value | unit | max. value)
0.001 s 2147483.647
Subcodes Lenze setting Info
C02776/1 1.000 s Max. activation time 1
C02776/2 1.000 s Max. activation time 2
C02776/3 1.000 s Max. activation time 3
C02776/4 1.000 s Max. activation time 4
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02779 | MOL_SetpointCurrent
Data type: UNSIGNED_32
Index: 21796
d
= 5524
h
From software version V7.0
Maximum current of the selected profile parameter set.
Basic function "Manual jog open loop
"
Display range (min. value | unit | max. value)
0.00 A 42949672.95
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02780 | MOL_dnState
Data type: INTEGER_32
Index: 21795
d
= 5523
h
From software version V7.0
Status of the basic function "Manual jog open loop
".
Display range (min. value | unit | max. value)
-2147483648 2147483647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1