13 Diagnostics & fault analysis
13.7 Error messages of the operating system
700
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Negative direction of rotation limited [0x00b8000a]
Speed has been limited [0x00b8000b]
Acceleration has been limited [0x00b8000c]
Deceleration has been limited [0x00b8000d]
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 10
Response (Lenze setting printed in bold) Setting: C02716/1 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Due to the setting of C02707 it was tried to traverse in
the impermissible negative direction of rotation.
• Only traverse in permissible (positive) direction of
rotation.
• Change setting of the permissible direction of
rotation (C02707
).
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 11
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
• The requested profile speed is higher than the
maximum speed set in C02703
and has been limited
to this speed.
• The required profile speed cannot be achieved with
the motor reference speed set in C00011
.
• Reduce speed of the traversing profile of the basic
function (manual jog, homing, or positioning).
• Increase maximum speed (C02703
).
Deactivate monitoring of the limit values by the basic
function "Limiter".
• Set motor reference speed correctly (C00011
).
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 12
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The requested profile acceleration is higher than the
maximum acceleration set in C02705
and has been
limited to this acceleration.
• Reduce acceleration of the traversing profile of the
basic function (manual jog, homing, or positioning).
• Increase maximum acceleration (C02705
).
Deactivate monitoring of the limit values by the basic
function "Limiter".
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 13
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The requested profile deceleration is higher than the
maximum acceleration set in C02705
and has been
limited to this acceleration.
• Reduce acceleration of the traversing profile of the
basic function (manual jog, homing, or positioning).
• Increase maximum acceleration (C02705
).
Deactivate monitoring of the limit values by the basic
function "Limiter".
Vista de pagina 699