Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 847
14 Parameter reference
14.2 Parameter list | C02104
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02104
C02108
C02109
C02110
Parameter | Name:
C02104 | Program auto-start
Data type: UNSIGNED_32
Index: 22471
d
= 57C7
h
Danger!
The controller enable generated by the application via a connection of the terminal 28 (RFR) with one of the digital
outputs DIGOUT_bOut(x) is is not permissible if the following functions are active:
"Auto-start after mains ON" (C00142
= "1") and "Program auto-start after mains switching" (C02104 ="1")
If this is not observed, the controller can start automatically after mains connection!
Automatic restart after mains connection
Activate application
Selection list (Lenze setting printed in bold)
0Off
1 Autom. after mains connection
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02108 | Program status
Data type: UNSIGNED_8
Index: 22467
d
= 57C3
h
Selection list (read only)
1 Program stopped
0 Program is running
2 Program stopped at breakpoint
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02109 | Program runtime
Data type: UNSIGNED_16
Index: 22466
d
= 57C2
h
Display range (min. value | unit | max. value)
0 μs 65535
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02110 | User code memory load
Data type: UNSIGNED_32
Index: 22465
d
= 57C1
h
From software version V2.0
Display range (min. value | unit | max. value)
0 % 100
Read access Write access CINH PLC STOP No transfer Scaling factor: 1