C00594
C00595
C00596
Parameter | Name:
C00594 | Resp. temp. sensor motor X7/X8
Data type: UNSIGNED_32
Index: 23981
d
= 5DAD
h
Response to motor temperature sensor error.
• The response to a too high motor temperature via PTC input T1/T2 can be selected in C00585
.
Motor temperature monitoring
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00595 | Resp. to CAN bus OFF
Data type: UNSIGNED_8
Index: 23980
d
= 5DAC
h
Response if CAN node switches to the bus off state.
"CAN on board" system bus
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00596 | Threshold max. speed reached
Data type: UNSIGNED_32
Index: 23979
d
= 5DAB
h
Threshold for speed monitoring
• The response to reaching the threshold can be selected in C00607
.
Setting range (min. value | unit | max. value) Lenze setting
50 rpm 50000 6500 rpm
Read access Write access CINH PLC STOP No transfer Scaling factor: 1