Lenze 9400 Manual de usuario Pagina 403

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 954
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 402
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 403
11 Basic drive functions
11.4 Manual jog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.4.3.2 Manual jog with step limitation
This function extension is available from software version V5.0 onwards!
This mode can be activated via the control input MAN_bStepMode.
In the "Manual jog with step limitation" mode the drive traverses by the "step distance"
parameterised in C02625
if a direction is requested via the control inputs MAN_bJogPositive/
MAN_bJogNegative. After traversing this distance, the drive stops.
A new positive edge for the routing request causes a restart of the function or a reset of the
distance counter, even if the drive is not at standstill yet.
If the routing request is reset before the distance is reached, the drive stops immediately (with
the deceleration set).
Note!
The two modes "Manual jog with step limitation" and "Manual jog with intermediate
stop" cannot be active at the same time.
If there is a simultaneous request via the control inputs MAN_bStepMode and
MAN_bIntermediateStopMode, only the "Manual jog with intermediate stop" mode is
active.Manual jog with intermediate stop
( 404)