13 Diagnostics & fault analysis
13.7 Error messages of the operating system
690
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CAN module (MXI1) SDO client: Faulty configuration [0x00a30000]
DFIN (MXI2): Track error A-/A [0x00aa0000]
DFIN (MXI2): Track error B-/B [0x00aa0001]
DFIN (MXI2): Track error Z-/Z [0x00aa0002]
Module ID (decimal) Error ID (decimal)
163: CAN module in MXI1: CAN-SDO client 0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CANopen communication module in MXI1: In the CAN
SDO client a configuration error has occurred.
• Faulty project download.
Invalid SDO client settings according to DS301V402 in
the Engineer or PLC Designer.
• Repeat download
• Correct CAN settings in the project and regenerate
project.
Module ID (decimal) Error ID (decimal)
170: Extension module - digital frequency in MXI2 0
Response (Lenze setting printed in bold) Setting: C14040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of the signal cable for track A.
• Check signal cable for track A.
•Check encoder.
Module ID (decimal) Error ID (decimal)
170: Extension module - digital frequency in MXI2 1
Response (Lenze setting printed in bold) Setting: C14040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of the signal cable for track B.
• Check signal cable for track B.
•Check encoder.
Module ID (decimal) Error ID (decimal)
170: Extension module - digital frequency in MXI2 2
Response (Lenze setting printed in bold) Setting: C14040 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of the signal cable for track Z.
• Check signal cable for track Z.
•Check encoder.