Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 877
14 Parameter reference
14.2 Parameter list | C02656
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02656
C02657
C02658
C02659
Parameter | Name:
C02656 | Actual position (homing)
Data type: INTEGER_32
Index: 21919
d
= 559F
h
Basic function "Homing"
Display range (min. value | unit | max. value)
-214748.3647 Unit 214748.3647
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02657 | HM_dnState
Data type: INTEGER_32
Index: 21918
d
= 559E
h
Bit coded status of the basic function "Homing".
Display range (min. value | unit | max. value)
-2147483648 2147483647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02658 | HM_dnHomePos_p
Data type: INTEGER_32
Index: 21917
d
= 559D
h
Display of the HM_dnHomePos_p input signal of the basic function "Homing".
Display range (min. value | unit | max. value)
-214748.3647 214748.3647
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02659 | Homing: Dig. signals
Data type: UNSIGNED_32
Index: 21916
d
= 559C
h
Display of the digital signals of the basic function "Homing".
Selection list (read only)
0 FALSE
1 TRUE
Subcodes Info
C02659/1 HM_bEnable
C02659/2 HM_bActivateHoming
C02659/3 HM_bHomingMark
C02659/4 HM_bLoadHomePos
C02659/5 HM_bResetHomePos
C02659/6 HM_bEnabled
C02659/7 HM_bActive
C02659/8 HM_bDone
C02659/9 HM_bHomePosAvailable
Read access Write access CINH PLC STOP No transfer Scaling factor: 1