13 Diagnostics & fault analysis
13.7 Error messages of the operating system
704
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Int. overflow C02621 (manual jog: Speed 2) [0x00b8001b]
Int. overflow C02622 (manual jog: Acceleration) [0x00b8001c]
Int. overflow C02623 (manual jog: Deceleration) [0x00b8001d]
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 27
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02621
.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 28
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02622
.
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 29
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"Max. position, speed, and acceleration that can be
displayed internally".
• Check machine parameters and adapt them if
required.
• Change setting in C02623
.