14 Parameter reference
14.2 Parameter list | C00640
808
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00640
C00641
C00642
C00643
Parameter | Name:
C00640 | Resp. to pole pos. id. monit.
Data type: UNSIGNED_32
Index: 23935
d
= 5D7F
h
From software version V4.0
Error response for abort of the pole position identification
Adjustment of the pole position identification
Selection list (Lenze setting printed in bold)
1Fault
4 Warning locked
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00641 | PLI 360° current amplitude
Data type: UNSIGNED_32
Index: 23934
d
= 5D7E
h
From software version V4.0
Percentage adjustment of the current amplitude for the pole position identification
Stop!
If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,
the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
1 % 1000 100 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00642 | PolePosId 360° ramp time
Data type: UNSIGNED_32
Index: 23933
d
= 5D7D
h
From software version V4.0
Percentage adjustment of the ramp time for the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
5 % 1000 100 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00643 | PLI 360° traversing direction
Data type: UNSIGNED_32
Index: 23932
d
= 5D7C
h
From software version V4.0
Selection of the traversing direction for the pole position identification
Adjustment of the pole position identification
Selection list (Lenze setting printed in bold)
0 Right rotating field
1 Left rotating field
Read access Write access CINH PLC STOP No transfer Scaling factor: 1