Lenze 9400 Manual de usuario Pagina 437

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 954
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 436
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 437
11 Basic drive functions
11.6 Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 13: negative direction to limit switch
Procedure:
1. Movement in negative direction with profile data set 1.
2. Positive edge of the travel range limit switch sets reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Negative travel range limit switch
Note!
The load machine can also leave the travel range limit switch. There follows a return to
the home position that was set with the positive edge of the travel range limit switch.
It is possible that, as a result, the machine will remain on an operated limit switch.
Therefore it is recommended to set a target position (C02643
) that is unequal to the
home position (C02642
) to release the activated limit switch again.